HISERV Feedback-Cable
Ⴠ
Bare copper, fine wire conductor toDINVDE0295 cl.5, BS6360 cl.5 and/orIEC60228 cl.5
Ⴠ
Special PVC core insulation
Ⴠ
Colour code
Tachofeedback-cable:blue, white, red, pink, green, yellow, brown,black, greyIncremental feedback-cable:brown, black/red, green/light-brown,white, pink/grey, violet/blue
Ⴠ
Single cores or pairs stranded in layer withoptimal lay-length pairs part no.22825)
Ⴠ
Core wrapping with film
Ⴠ
Drain wire
Ⴠ
Tinned copper braided screening, coverageapprox. 85%
Ⴠ
Special PVC outer sheath
Ⴠ
Colour grey (RAL7001)
Ⴠ
with meter marking, change-over in 2011
|
Rated voltage :
|
Uo/U 600/1000V
|
|
Test voltage :
|
4000V
|
|
Insulation resistance :
|
(+20°C):≧20MΩx km
|
|
Bending radius: :
|
stationary : 4 x cable diameterØ
flexible : 7.5 x cable diameterØ |
|
Temperature range :
|
stationary : -50°C - 90°C
flexible : -40°C - 80°C |
|
Flame retardant :
|
IEC 60332-1
|
Order Number |
Number of cores × Nominal cross-sectional area mm² |
Cable diameter ~mm |
Copper weight ~kg/km |
Cable weight ~kg/km |
316110 |
12x0,25 |
7,5 |
65,0 |
90 |
316111 |
3x2x0,14+4x0,14+4x0,25+2x0,5 |
10,8 |
92,0 |
148 |
316112 |
4x2x0,34+4x0,5 |
9,5 |
77,0 |
145 |
Extensively oil resistant, foroil-/ chemical Resistance see Techn. Information table
PVC self-extinguishing and flame resistant to VDE0482 part265-2-1/ EN 50265-2-1/IEC 60332-1 (equivalent to DIN VDE 0472 part804 test typeB)
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers