HIFLEX CPZ
● blanke Cu-Litze, feindrähtig
● Litzenaufbau nach VDE 0295,
Klasse 5 bzw. IEC 60228 cl. 5
● Adern Spezial-PVC
● schwarze Adern mit fortlfd. weißen
Ziffernaufdruck
● Schutzleiter grüngelb
(ab 3-adrig) in der Außenlage
● Adern mit optimalen
Schlaglängen in Lagen verseilt
● Innenmantel aus Spezial-PVC
● verzinntes Kupfergeflecht
● Außenmantel PUR, ölbeständig,
UV-beständig
● Mantelfarbe grau, RAL 7001
|
Rated voltage :
|
Uo/U 300/500V
|
|
Test voltage :
|
3000V
|
|
Insulation resistance :
|
(+20°C):≧20MΩx km
|
|
Bending radius: :
|
stationary : 5 x cable diameterØ
flexible : 10 x cable diameterØ |
|
Temperature range :
|
stationary : -40°C - 80°C
flexible : -5°C - 70°C |
|
Radiation resistance :
|
≤80×10cJ/kg
|
|
Flame retardant :
|
IEC 60332-1
|
Order Number |
Number of cores × Nominal cross-sectional area mm² |
Cable diameter ~mm |
Copper weight ~kg/km |
Cable weight ~kg/km |
122001 |
2x0,75 |
7,5 |
47,0 |
87 |
122002 |
3G0,75 |
8,0 |
54,0 |
100 |
122003 |
3x0,75 |
8,0 |
54,0 |
100 |
122004 |
4G0,75 |
8,5 |
77,0 |
116 |
122005 |
4x0,75 |
8,5 |
77,0 |
116 |
122006 |
5G0,75 |
9,0 |
86,0 |
130 |
122007 |
5x0,75 |
9,0 |
86,0 |
130 |
122008 |
7G0,75 |
9,7 |
93,0 |
163 |
122009 |
7x0,75 |
9,7 |
93,0 |
163 |
122010 |
12G0,75 |
12,3 |
140,0 |
245 |
122011 |
18G0,75 |
14,7 |
222,0 |
355 |
122012 |
25G0,75 |
16,6 |
280,0 |
465 |
122013 |
34G0,75 |
19,0 |
420,0 |
600 |
122014 |
41G0,75 |
20,8 |
504,0 |
730 |
122015 |
2x1,0 |
8,0 |
51,0 |
98 |
122016 |
3G1,0 |
8,3 |
79,0 |
111 |
122017 |
3x1,0 |
8,3 |
79,0 |
111 |
122018 |
4G1,0 |
8,8 |
88,0 |
130 |
122019 |
4x1,0 |
8,8 |
88,0 |
130 |
122020 |
5G1,0 |
9,5 |
92,0 |
153 |
122021 |
7G1,0 |
10,3 |
113,0 |
185 |
122022 |
12G1,0 |
13,5 |
197,0 |
308 |
122023 |
18G1,0 |
15,6 |
269,0 |
418 |
122024 |
25G1,0 |
17,5 |
380,0 |
542 |
122025 |
34G1,0 |
20,5 |
519,0 |
738 |
122026 |
41G1,0 |
22,1 |
612,0 |
863 |
122027 |
2x1,5 |
8,5 |
78,0 |
117 |
122028 |
3G1,5 |
9,0 |
87,0 |
136 |
122029 |
3x1,5 |
9,0 |
87,0 |
136 |
122030 |
4G1,5 |
9,7 |
100,0 |
164 |
122031 |
4x1,5 |
9,7 |
100,0 |
164 |
122032 |
5G1,5 |
10,5 |
122,0 |
189 |
122033 |
5x1,5 |
10,5 |
122,0 |
189 |
122034 |
7G1,5 |
11,5 |
152,0 |
239 |
122035 |
7x1,5 |
11,5 |
152,0 |
239 |
122036 |
12G1,5 |
15,0 |
270,0 |
395 |
122037 |
18G1,5 |
17,3 |
312,0 |
538 |
122038 |
25G1,5 |
20,1 |
575,0 |
743 |
122039 |
34G1,5 |
22,0 |
756,0 |
960 |
122040 |
41G1,5 |
24,8 |
875,0 |
1120 |
122041 |
3G2,5 |
10,4 |
122,0 |
192 |
122042 |
4G2,5 |
11,5 |
165,0 |
235 |
122043 |
5G2,5 |
12,7 |
200,0 |
283 |
122044 |
7G2,5 |
13,9 |
263,0 |
370 |
122045 |
12G2,5 |
17,3 |
475,0 |
583 |
122046 |
4G4,0 |
13,5 |
240,0 |
346 |
122047 |
5G4,0 |
14,7 |
280,0 |
412 |
122048 |
4G6,0 |
15,9 |
320,0 |
485 |
122049 |
5G6,0 |
17,3 |
373,0 |
577 |
122050 |
4G10,0 |
19,2 |
560,0 |
735 |
122051 |
4G16,0 |
22,3 |
805,0 |
1343 |
Verwendung als Energie- oder Verbin-
dungsleitung, alsMeß-, Kontroll- und Steu-
erleitung im Werkzeugmaschinenbau, An-
agenbau, an Fließbändern und Fertigungs-
straßen.
Geeignet für feste Verlegung oder flexible
Anwendungen bei freier, nicht ständig wie-
derkehrender Bewegung ohne zwangswei-
se Bewegungsführung und ohne Zugbean-
spruchung, in trockenen und feuchtenRäu-
men als auch im Freien einsetzbar. Bei Ein-
satz im Freien muß der Temperaturbereich
beachtet werden.
Das Kupferabschirmgeflecht verhindert
elektrische und magnetische Störfelder
von der Steuerleitung in die Umgebung als
auch aus der Umgebung auf die innenge-führten Adern.