HIFLEX CPZ 0.6/1KV
● blanke Cu-Litze, feindrähtig
● Litzenaufbau nach VDE 0295,
Klasse 5 bzw. IEC 60228 cl. 5
● Adern Spezial-PVC
● schwarze Adern mit fortlfd. weißen
Ziffernaufdruck
● Schutzleiter grüngelb
(ab 3-adrig) in der Außenlage
● Adern mit optimalen
Schlaglängen in Lagen verseilt
● Innenmantel aus Spezial-PVC
● verzinntes Kupfergeflecht
● Außenmantel PUR, ölbeständig,
UV-beständig
● Mantelfarbe grau, RAL 7001
|
Rated voltage :
|
Uo/U 600/1000V
|
|
Test voltage :
|
4000V
|
|
Insulation resistance :
|
(+20°C):≧20MΩx km
|
|
Bending radius: :
|
stationary : 10 x cable diameterØ
flexible : 5 x cable diameterØ |
|
Temperature range :
|
stationary : -40°C - 80°C
flexible : -5°C - 70°C |
|
Radiation resistance :
|
≤80×10cJ/kg
|
|
Flame retardant :
|
IEC 60332-1
|
Order Number |
Number of cores × Nominal cross-sectional area mm² |
Cable diameter ~mm |
Copper weight ~kg/km |
Cable weight ~kg/km |
128101 |
2x0,75 |
7,5 |
47,0 |
87 |
128102 |
3G0,75 |
8,0 |
54,0 |
100 |
128103 |
3x0,75 |
8,0 |
54,0 |
100 |
128104 |
4G0,75 |
8,5 |
77,0 |
116 |
128105 |
4x0,75 |
8,5 |
77,0 |
116 |
128106 |
5G0,75 |
9,0 |
86,0 |
130 |
128107 |
5x0,75 |
9,0 |
86,0 |
130 |
128108 |
7G0,75 |
9,7 |
93,0 |
163 |
128109 |
7x0,75 |
9,7 |
93,0 |
163 |
128110 |
12G0,75 |
12,3 |
140,0 |
245 |
128111 |
18G0,75 |
14,7 |
222,0 |
355 |
128112 |
25G0,75 |
16,6 |
280,0 |
465 |
128113 |
34G0,75 |
19,0 |
420,0 |
600 |
128114 |
41G0,75 |
20,8 |
504,0 |
730 |
128115 |
2x1,0 |
8,0 |
51,0 |
98 |
128116 |
3G1,0 |
8,3 |
79,0 |
111 |
128117 |
3x1,0 |
8,3 |
79,0 |
111 |
128118 |
4G1,0 |
8,8 |
88,0 |
130 |
128119 |
4x1,0 |
8,8 |
88,0 |
130 |
128120 |
5G1,0 |
9,5 |
92,0 |
153 |
128121 |
7G1,0 |
10,3 |
113,0 |
185 |
128122 |
12G1,0 |
13,5 |
197,0 |
308 |
128123 |
18G1,0 |
15,6 |
269,0 |
418 |
128124 |
25G1,0 |
17,5 |
380,0 |
542 |
128125 |
34G1,0 |
20,5 |
519,0 |
738 |
128126 |
41G1,0 |
22,1 |
612,0 |
863 |
128127 |
2x1,5 |
8,5 |
78,0 |
117 |
128128 |
3G1,5 |
9,0 |
87,0 |
136 |
128129 |
3x1,5 |
9,0 |
87,0 |
136 |
128130 |
4G1,5 |
9,7 |
100,0 |
164 |
128131 |
4x1,5 |
9,7 |
100,0 |
164 |
128132 |
5G1,5 |
10,5 |
122,0 |
189 |
128133 |
5x1,5 |
10,5 |
122,0 |
189 |
128134 |
7G1,5 |
11,5 |
152,0 |
239 |
128135 |
7x1,5 |
11,5 |
152,0 |
239 |
128136 |
12G1,5 |
15,0 |
270,0 |
395 |
128137 |
18G1,5 |
17,3 |
312,0 |
538 |
128138 |
25G1,5 |
20,1 |
575,0 |
743 |
128139 |
34G1,5 |
22,0 |
756,0 |
960 |
128140 |
41G1,5 |
24,8 |
875,0 |
1120 |
128141 |
3G2,5 |
10,4 |
122,0 |
192 |
128142 |
4G2,5 |
11,5 |
165,0 |
235 |
128143 |
5G2,5 |
12,7 |
200,0 |
283 |
128144 |
7G2,5 |
13,9 |
263,0 |
370 |
128145 |
12G2,5 |
17,3 |
475,0 |
583 |
128146 |
4G4,0 |
13,5 |
240,0 |
346 |
128147 |
5G4,0 |
14,7 |
280,0 |
412 |
128148 |
4G6,0 |
15,9 |
320,0 |
485 |
128149 |
5G6,0 |
17,3 |
373,0 |
577 |
128150 |
4G10,0 |
19,2 |
560,0 |
735 |
128151 |
4G16,0 |
22,3 |
805,0 |
1343 |
Verwendung als Energie- oder Verbin-
dungsleitung, alsMeß-, Kontroll- und Steu-
erleitung im Werkzeugmaschinenbau, An-
lagenbau, an Fließbändern und Fertigungs-
straßen.
Geeignet für feste Verlegung oder flexible
Anwendungen bei freier, nicht ständig wie-
derkehrender Bewegung ohne zwangswei-
se Bewegungsführung und ohne Zugbean-
spruchung, in trockenen und feuchtenRäu-
men als auch im Freien einsetzbar. Bei Ein-
satz im Freien muß der Temperaturbereich
beachtet werden.
Das Kupferabschirmgeflecht verhindert
elektrische und magnetische Störfelder
von der Steuerleitung in die Umgebung als
auch aus der Umgebung auf die innenge-führten Adern.