NYCWY
● Cu-Leiter, blank,
ein- oder mehrdrähtig,
rund oder sektorförmig
● Aderisolation PVC
● Aderfarben gemäß VDE 0293
● Adern konzentrisch mit optimalen
Schlaglängen verseilt
● gemeinsame Aderumhüllung
● konzentrischer Leiter
Innenlage:
wellenförmige (Ceander),
runde, blanke Cu-Drähte
Außenlage:
Cu-Band als Gegenwendel
● Mantelisolation PVC, flammwidrig
● Mantelfarbe Schwarz
|
Rated voltage :
|
Uo/U 600/1000V
|
|
Test voltage :
|
4000V
|
|
Insulation resistance :
|
(+20°C):≧20MΩx km
|
|
Bending radius: :
|
stationary : 12 x cable diameterØ
flexible : 50 x cable diameterØ |
|
Temperature range :
|
stationary : -30°C - 70°C
flexible : -5°C - 50°C |
|
Radiation resistance :
|
≤80×10cJ/kg
|
|
Flame retardant :
|
IEC 60332-1
|
Order Number |
Number of cores × Nominal cross-sectional area mm² |
Cable diameter ~mm |
Copper weight ~kg/km |
Cable weight ~kg/km |
135001 |
2x10 re/10 |
20 |
312 |
600 |
135002 |
2x16 re/16 |
21 |
489 |
850 |
135003 |
2x25 rm/25 |
24 |
763 |
1200 |
135004 |
3x10 re/10 |
20 |
408 |
730 |
135005 |
3x16 re/16 |
22 |
643 |
1000 |
135006 |
3x25 rm/16 |
26 |
902 |
1550 |
135007 |
3x35 sm/16 |
27.5 |
1190 |
1750 |
135008 |
3x50 sm/25 |
31 |
1723 |
2250 |
135009 |
3x70 sm/35 |
33 |
2410 |
2950 |
135010 |
3x95 sm/50 |
38.5 |
3296 |
4100 |
135011 |
3x120 sm/70 |
41.5 |
4236 |
5050 |
135012 |
3x150 sm/70 |
45.5 |
5100 |
6000 |
135013 |
3x185 sm/95 |
50 |
6383 |
7550 |
135014 |
3x240 sm/120 |
57 |
8242 |
9950 |
135015 |
3x25 rm/25 |
27 |
1003 |
1600 |
135016 |
3x35 sm/35 |
28 |
1402 |
1850 |
135017 |
3x50 sm/50 |
30.5 |
2000 |
2450 |
135018 |
3x70 sm/70 |
34 |
2796 |
3350 |
135019 |
3x95 sm/95 |
38.5 |
3791 |
4550 |
135020 |
3x120 sm/120 |
42 |
4786 |
5550 |
135021 |
3x150 sm/150 |
46 |
5970 |
6900 |
135022 |
3x185 sm/185 |
51 |
7363 |
8500 |
135023 |
4x10 re/10 |
21 |
504 |
890 |
135024 |
4x16 re/16 |
23.5 |
796 |
1250 |
135025 |
4x25 rm/16 |
29 |
1142 |
1800 |
135026 |
4x35 sm/16 |
29 |
1526 |
2050 |
135027 |
4x50 sm/25 |
33.5 |
2203 |
2700 |
135028 |
4x70 sm/35 |
37 |
3082 |
3750 |
135029 |
4x95 sm/50 |
43 |
4208 |
5000 |
135030 |
4x120 sm/70 |
46.5 |
5388 |
6350 |
135031 |
4x150 sm/70 |
51.5 |
6540 |
7650 |
135032 |
4x185 sm/95 |
56.5 |
8159 |
9550 |
135033 |
4x240 sm/120 |
62.5 |
10546 |
11600 |
Für Energieübertragung im Nennspan-
nungsbereich 600/1000 V bei fester Ver-
legung ohne die Gefahr mechanischer
Einwirkungen im Innenbereich, im Freien,
im Erdreich, in Beton und Wasser.
Der konzentrische Leiter „C“ darf als Mittel-,Schutz- oder Nullleiter verwendet werden.