HOME PRODUCT Electronic cables

HIFLEX LiYCY-CY-TP
pdf

Twisted-pair data cable with screened pairs and overall copper braided screening;preferred EMC compatible cable type

  • Structure chart
  • status of use
  • Certification
  • Electrical and technical specifications
  • Design
  • Applications

Rated voltage:Uo/U 300/500V

Test voltage:4000V

Insulation resistance at +20° C:≥:(+20°C):≧20MΩx km

Bending radius:

      stationary :4 x cable diameterØ

       flexible:15 x cable diameterØ

Temperature range:

       flexible:-5°C - 70°C

      stationary:-40°C - 80°C

Radiation resistance:≤80×10cJ/kg

Flame retardant:IEC 60332-1

测试电压:0.14mm² 1200 V

                 0.25mm² 2000 V

导体电阻:0.14mm² 138 Ω/km

                 0.25mm² 77.8 Ω/km

阻抗(20°C):0.14mm² 535Ω/1kHz

                    0.25mm² 395Ω/1kHz/


● Stranded bare Cu conductor, fine wire

● Strand structure to VDE 0295 class 5 / IEC

60228 class 5(exception 0.34 mm2= stranded

bare Cu conductor 7 x 0.25 mm)

● Core insulation: special PVC

● Core identification to DIN 47100

● 2 cores twisted in pairs

● Each pair individually enclosed by a braided

screen made of tinned copper wire

● Each pair individually insulated with a PVC jacket

● Pairs twisted in layers, with optimal lay lengths

● Lapped with plastic film

● Braided screening made of tinned copper wires

● Outer sheath: special PVC

● Sheath colour: RAL 7032 grey


Flexible connecting cable for electronic control pulse transmission in data transmission applications. The individual pairs of cores are screened to avoid mutual interference between different circuits. The additional PVC protection against accidental contact prevents interference by external earthing. The twisted pairs are provided with a tinned overall copper screening to avoid external interference. Suitable for stationary installation or flexible applications with unrestricted mobility, not constantly recurrent movements without forced movement control and without exposure to tensile load.

When used for outdoor applications, adequate protection against direct exposure to sunlight must be ensured and the specified temperature limits must be observed.


  • Material list
Part No. No.cores Xcross-sec.
mm²
Outer Øca.
mm
Cop.weight
kg / km
Weight ca.
kg / km
205001 2x2x0,14 7,5 35,0 95
205002 3x2x0,14 8,0 45,0 105
205003 4x2x0,14 9,5 54,0 120
205004 5x2x0,14 10,5 62,0 160
205005 6x2x0,14 11,0 71,0 188
205006 7x2x0,14 11,5 82,0 230
205007 8x2x0,14 13,0 97,0 257
205008 9x2x0,14 14,0 110,0 280
205009 10x2x0,14 14,3 120,0 320
205010 12x2x0,14 15,1 140,0 382
205011 16x2x0,14 17,2 190,0 440
205012 20x2x0,14 18,0 230,0 520
205013 2x2x0,25 10,2 63,0 125
205014 3x2x0,25 11,0 80,0 150
205015 4x2x0,25 12,4 112,0 210
205016 5x2x0,25 13,5 136,0 235
205017 6x2x0,25 15,1 149,0 290
205018 7x2x0,25 15,1 175,0 300
205019 8x2x0,25 16,5 189,0 345
205020 10x2x0,25 19,5 267,0 435
205021 12x2x0,25 20,1 307,0 470
205022 16x2x0,25 22,8 363,0 610
205023 20x2x0,25 23,6 390,0 750
205024 24x2x0,25 26,0 460,0 900
205025 32x2x0,25 29,5 576,0 1220
205026 48x2x0,25 35,0 845,0 1490
205027 2x2x0,34 12,0 67,0 130
205028 3x2x0,34 13,4 90,0 160
205029 4x2x0,34 15,3 121,0 220
205030 6x2x0,34 18,2 156,0 310
205031 8x2x0,34 20,4 198,0 360
205032 2x2x0,50 13,0 91,0 193
205033 3x2x0,50 13,4 110,0 210
205034 4x2x0,50 14,6 157,0 272
205035 6x2x0,50 18,0 191,0 396
205036 8x2x0,50 19,6 225,0 420
205037 2x2x0,75 12,2 95,0 205
205038 3x2x0,75 13,5 123,7 265
205039 4x2x0,75 15,0 162,0 325
205040 8x2x0,75 22,0 245,0 634