Rated voltage:Uo/U 600/1000V
Test voltage:4000V
Insulation resistance at +20° C:≥:(+20°C):≧20MΩx km
Bending radius:
stationary :3 x cable diameterØ
flexible:7.5 x cable diameterØ
Temperature range:
flexible:-5°C - 90°C
stationary:-40°C - 90°C
Radiation resistance:≤80×10cJ/kg
Flame retardant:IEC 60332-1
● Bare copper, extra fine wire conductors,
to DIN VDE 0295 cl. 6, col. 4, BS 6360 cl. 6
and IEC 60228 cl. 6, however by 185 mm²
up to 300 mm² with reduced single wire-ø,
max. 0,30 mm
● 1. Core insulation of special PVC, TI3 to
DIN VDE 0281 part 1DIN VDE 0281 part 3,
colour black or green-yellow
2. Core insulation (jacket) of special PVC,
YM5 to DIN VDE 0207 part 5
● colour black (RAL 9005)
High flexible special single core cables for drag chains are used for flexible use for medium mechanical stresses with free mov ement without tensile stress or forced movements in dry, moist and wet rooms. These two-norm cables primarily designed for exportorientated m achinery manufacturer for flexible applications in machineries, machine tools, robot technics, for movable automated machinery parts.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems.
Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain c ables, see lead text.
Part No. | No.cores Xcross-sec. mm² |
Outer Øca. mm |
Cop.weight kg / km |
Weight ca. kg / km |
---|